Open-front booths with front extraction for bulky parts, sanding, preparation and product application: sized from the area of the opening.

01 / Extraction booths
When to choose a booth
When the part is too large for a table, when the operator moves around it, or when the emission is diffuse: sanding large surfaces, preparation and filling, application of adhesives, varnishes or paint, blowing off.
The booth encloses the working area on three sides and a ceiling; air enters through the open face, sweeps over the part and leaves through the filter wall at the back.
02 / Extraction booths
The airflow is calculated on the opening
For an open-front booth, the airflow is the area of the opening multiplied by the inlet air velocity: 0.5 to 1 m/s when the pollutant is not projected outwards (INRS ED 695). A 3 m × 2.5 m opening at 0.5 m/s needs 13,500 m³/h.
Reducing the opening reduces the airflow accordingly: curtains or adjustable side panels adapt the booth to the size of the parts.
03 / Extraction booths
Placing the operator in the right spot
The operator works between the air inlet and the part, never between the part and the filter wall: the airflow then carries the pollutant away from the breathing zone.
For paint and solvents, the air is discharged outdoors and the extracted air must be made up by a fresh-air inlet, heated in winter.
04 / Extraction booths
What we need to quote
The size of the largest parts, the operation carried out and the products used (safety data sheets), the space available and the possible location of the discharge.
Useful answers
Frequently asked questions
What airflow for an extraction booth?
The area of the opening multiplied by 0.5 to 1 m/s. A 6 m² opening at 0.5 m/s needs about 11,000 m³/h.
Is a paint booth subsidised?
In France, for companies with fewer than 50 employees, the French Health Insurance offers “Paint booth capture” and “Preparation area capture” subsidies, at 70% of the amount excluding VAT.
Continue your selection
Related solutions and guides
Your industrial project
Tell us what you need.
Give us the size of the parts, the operation and the products used: we size the booth and its extraction, and send you a quote.
Contact us
Let’s talk about your installation.
A technician from our engineering office studies your needs and proposes the right solution for your workshop: machine, capture, ductwork and filtration.
Reply within 48 working hours.
Your request, step by step
-
1
You describe your needs
Pollutant, workstations, constraints: a few lines are enough. A photo of the installation helps us a lot.
-
2
Our engineering office studies it
Capture, airflow, ductwork and filtration are sized for your site, together with you if anything needs clarifying.
-
3
You receive a written proposal
Machine, options and price, in detail: you decide with full knowledge of the facts.
- Since 1994in industrial air treatment
- In-house engineering officefrom design to supply
- All brandsfilters and spare parts
- French Fabnetwork member